A gate can be controlled with an SW module only if the control unit has a dry contact command input.
In brief: The module must replicate the push button or control selector; it must not be connected directly to the motor.
Which module
| Need | Module to consider |
|---|---|
| One independent command | SW0901-E or SW0901-F |
| Two independent commands | SW0702-E or SW0702-F |
Essential checks
- Dry contact input present on the control unit.
- Type of command required by the manufacturer.
- Pulse duration.
- Power supply available for the module.
- Wi-Fi coverage at the installation point.
Setup
- Have the module output connected to the command input of the control unit.
- Add the module to Freedompro Home.
- Configure the output as a dry contact.
- Set Auto Off to generate the required pulse.
- Test the command with the gate in safe conditions and under visual control.
Do not bypass photocells, safety devices or the control unit logic. The installation must be checked by a qualified technician.